IDENTIFIKASI BAKTERI Stapylococcus aureus DAN Pseudomonas aeruginosa PADA ALAT-ALAT DI RUANG IGD RUMAH SAKIT “X” SURAKARTA

Na’imah, Lutfi Afiatu (2025) IDENTIFIKASI BAKTERI Stapylococcus aureus DAN Pseudomonas aeruginosa PADA ALAT-ALAT DI RUANG IGD RUMAH SAKIT “X” SURAKARTA. Diploma thesis, Universitas Setia Budi.

[thumbnail of INTISARI dan ABSTRACT.pdf] Text
INTISARI dan ABSTRACT.pdf

Download (503kB)
[thumbnail of form pernyataan publikasi lutfi afiatu (1).pdf] Text
form pernyataan publikasi lutfi afiatu (1).pdf

Download (130kB)
[thumbnail of COVER - BAB I.pdf] Text
COVER - BAB I.pdf

Download (1MB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (605kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf

Download (538kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Repository staff only

Download (554kB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Repository staff only

Download (417kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf
Restricted to Repository staff only

Download (427kB)
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Repository staff only

Download (820kB)

Abstract

Rumah sakit merupakan institusi pelayanan kesehatan yang menyelenggarakan pelayanan kesehatan perorangan secara yang menyediakan pelayanan rawat inap, rawat jalan dan gawat darurat. Penelitian sebelumnya menunjukkan bahwa bakteri seperti Staphylococcus aureus dan Pseudomonas aeruginosa sering mencemari lingkungan rumah sakit, terutama pada alat medis bedah minor yang digunakan di ruang UGD, sehingga meningkatkan risiko infeksi. Penelitian ini bertujuan untuk mengidentifikasi adanya cemaran Staphylococcus aureus dan Pseudomonas aeruginosa pada alat-alat di ruang IGD. Identifikasi adanya bakteri Staphylococcus aureus dan Pseudomonas aeruginosa pada alat-alat di ruang IGD Rumah Sakit “X” Surakarta masing-masing berjumlah 10 sampel. Sampel diambil melalui usap, diinokulasikan ke BHI dan diuji di Laboratorium Mikrobiologi Universitas Setia Budi dengan penanaman pada media selektif VJA untuk Staphylococcus aureus, dan PSA untuk Pseudomonas aeruginosa. Hasil positif pada media VJA dan PSA dilanjutkan uji biokimia untuk masing-spesies bakteri yang diidentifikasi. Hasil identifikasi Staphylococcus aureus dan Pseudomonas aeruginosa pada alat-alat di ruang IGD Rumah Sakit “X” Surakarta sebanyak 4 dari alat-alat positif terdapat Staphylococcus aureus. Sementara itu, dari 10 sampel tidak terdeteksi Pseudomonas aeruginosa. Penelitian menunjukan bahwa Staphylococcus aureus lebih banyak ditemukan pada alat-alat medis karena faktor kontaminasi dan penyebaran melalui udara ruangan. Rumah sakit perlu memperkuat pengawasan lingkungan, terutama terkait alat medis di ruang IGD, untuk mengurangi risiko infeksi nosokomial. Hospitals are healthcare institutions that provide comprehensive individual healthcare services, including inpatient care, outpatient care, and emergency care. Previous studies have shown that bacteria such as Staphylococcus aureus and Pseudomonas aeruginosa frequently contaminate hospital environments, particularly on minor surgical instruments used in emergency rooms, thereby increasing the risk of infection. This study aims to identify the presence of Staphylococcus aureus and Pseudomonas aeruginosa contamination on instruments in the emergency room. The identification of Staphylococcus aureus and Pseudomonas aeruginosa bacteria on instruments in the emergency room of Hospital “X” Surakarta involved 10 samples each. Samples were collected via swabs, inoculated onto BHI, and tested at the Microbiology Laboratory of Setia Budi University using selective media: VJA for Staphylococcus aureus and PSA for Pseudomonas aeruginosa. Positive results on VJA and PSA media were followed by biochemical testing for each identified bacterial species. The identification of Staphylococcus aureus and Pseudomonas aeruginosa on instruments in the emergency room of "X" Hospital, Surakarta, revealed that four of the instruments tested positive for Staphylococcus aureus. Meanwhile, no Pseudomonas aeruginosa was detected in 10 samples. The study showed that Staphylococcus aureus was more commonly found on medical instruments due to contamination and airborne transmission. Hospitals need to strengthen environmental surveillance, particularly regarding medical instruments in the ED, to reduce the risk of nosocomial infections.
Item Type: Thesis (Diploma)
Uncontrolled Keywords: Peralatan, ruang IGD, Staphylococcus aureus, Pseudomonas aeruginosa. Equipment, ED, Staphylococcus aureus, Pseudomonas aeruginosa
Subjects: Q Science > Q Science (General)
Q Science > QR Microbiology
Divisions: Universitas Setia Budi > Fakultas Ilmu Kesehatan > D3 Analis Kesehatan
Depositing User: Unnamed user with email baa.si@setiabudi.ac.id
Date Deposited: 23 Dec 2025 02:42
Last Modified: 23 Dec 2025 02:42
URI: https://eprints.setiabudi.ac.id/id/eprint/72

Actions (login required)

View Item
View Item